Default Values
SERIES 9130 Factory defaults |
|
|
||
June 28, 2011. |
|
|
||
Parameter |
Default |
Factory Setting |
Customer Setting |
|
Host 232 baud |
19200 |
|
|
|
Host 232 Mode |
Modbus/DF1 Master |
|
|
|
Host 232-2 baud |
19200 |
|
|
|
Host 232-2 Mode |
Modbus |
|
|
|
Host 485 baud |
19200 |
|
|
|
Host 485 Mode |
Modbus |
|
|
|
Host 485 Address |
1 |
|
|
|
Client 1 baud |
19200 |
|
|
|
Client 1 Mode |
Modbus |
|
|
|
Client 2 baud |
19200 |
|
|
|
Client 2 Mode |
Modbus |
|
|
|
Pass code 1 |
1 |
|
|
|
Pass code 2 |
2 |
|
|
|
Web code 1 |
111 |
|
|
|
Web code 2 |
222 |
|
|
|
Web change enable |
yes |
|
|
|
PV 1 Name |
Temperature 1 |
|
|
|
Furnace Name |
Temper 1,2, & 3 |
|
|
|
|
|
|
|
|
AD 1 filter time |
0 |
|
|
|
AD 2 filter time |
0 |
|
|
|
AD 3 filter time |
0 |
|
|
|
|
|
|
|
|
IN 1 initial scale |
0 |
|
|
|
IN 1 Full scale |
1000 |
|
|
|
IN 2 initial scale |
0 |
|
|
|
IN 2 Full scale |
10000 |
|
|
|
IN 3 initial scale |
0 |
|
|
|
IN 3 Full scale |
10000 |
|
|
|
|
|
|
|
|
|
|
|
|
|
IN 1 Decimal place |
0 |
|
|
|
IN 2 Decimal place |
0 |
|
|
|
IN 3 Decimal place |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Parameter |
Default |
Factory Setting |
Customer Setting |
|
Setpoint lower limit, all |
-9999 |
|
|
|
Setpoint upper limit, all |
29999 |
|
|
|
Event hold |
none |
|
|
|
Event hold polarity |
all N.O. |
|
|
|
Hold instrument |
none |
|
|
|
Hold PV min |
2000 |
|
|
|
Hold PV max |
0 |
|
|
|
Event run |
None (-1) |
|
|
|
Event reset |
None (-1) |
|
|
|
Client Instrument setups |
None |
|
|
|
Zone Assignments |
None |
|
|
|
|
|
|
|
|
Quench instrument |
Instrument 2 |
|
|
|
Quench events |
6 speed, 7 end |
|
|
|
Temperature default wait limit |
15 |
|
|
|
PV Switch Action |
None |
|
|
|
IP address |
192.168.0.200 |
|
|
|
IP net mask |
255.255.255.0 |
|
|
|
IP gateway |
192.168.1.1 |
|
|
|
Temperature mode |
Fahrenheit |
|
|
|
Loop 1 setpoint |
0 |
|
|
|
Loop 1 prop band |
4.0 |
|
|
|
Loop 1 reset |
0.1 |
|
|
|
Loop 1 rate |
0 |
|
|
|
Loop 1 cycle time |
60 |
|
|
|
Loop 1 auto/manual |
auto |
|
|
|
Loop 1 integral preset |
0 |
|
|
|
Loop 2 setpoint |
0 |
|
|
|
Loop 2 prop band |
4.0 |
|
|
|
Loop 2 reset |
0.1 |
|
|
|
Loop 2 rate |
0 |
|
|
|
Loop 2 cycle time |
60 |
|
|
|
Loop 2 auto/manual |
manual |
|
|
|
Loop 2 integral preset |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
Parameter |
Default |
Factory Setting |
Customer Setting |
|
Analog Output 1 Assignment |
Loop 1 inc |
|
|
|
Analog Output 1 offset |
0 |
|
|
|
Analog Output 1 Range |
200 |
|
|
|
Analog Output 2 Assignment |
PV1 retrans |
|
|
|
Analog Output 2 offset |
0 |
|
|
|
Analog Output 2 Range |
3000 |
|
|
|
Relay 1 Assignment |
Loop 1 Fwd |
|
|
|
Relay 2 Assignment |
Loop 1 Rev |
|
|
|
Relay 3 Assignment |
Event 0 |
|
|
|
Relay 4 Assignment |
Event 1 |
|
|
|
Relay 5 Assignment |
Event 2 |
|
|
|
Relay 6 Assignment |
Event 3 |
|
|
|
Relay 7 Assignment |
Alarm 1 |
|
|
|
Relay 8 Assignment |
Alarm 2 |
|
|
|
PID Loop 1 Mode |
Single Reverse |
|
|
|
PID Loop 1 Low Limit |
0 |
|
|
|
PID Loop 1 High Limit |
100 |
|
|
|
PID Loop 1 Source |
Input 1 |
|
|
|
PID Loop 1 0 SP Stops Control |
No |
|
|
|
PID Loop 2 Mode |
Single Reverse |
|
|
|
PID Loop 2 Low Limit |
0 |
|
|
|
PID Loop 2 High Limit |
100 |
|
|
|
PID Loop 2 Source |
Off |
|
|
|
PID Loop 2 0 SP Stops Control |
No |
|
|
|
Alarm 1 Setpoint |
9999 |
|
|
|
Alarm 1 Alarm Type |
PV1 Process High |
|
|
|
Alarm 1 Hysteresis |
1 |
|
|
|
Alarm 2 Setpoint |
9999 |
|
|
|
Alarm 2 Alarm Type |
PV1 Process High |
|
|
|
Alarm 2 Hysteresis |
1 |
|
|
|
Alarm 3 Setpoint |
9999 |
|
|
|
Alarm 3 Alarm Type |
PV1 Process High |
|
|
|
Alarm 3 Hysteresis |
1 |
|
|
|
Clear events at end of recipe |
Yes |
|
|